U shape coriolis mass flow meter
● U-shape bent tube design
● For all industries, and all process and custody transfer applications.
● Universal measuring principle for liquids and gases
● Multivariable measurement- simultaneous measuring of mass flow, density, temperature
● High measuring accuracy: typically ±0.2%, ±0.1% o.r., optionally: ±0.05%
● Measuring principle independent of the physical fluid properties and the flow profile
● Easy to install (low risk of gas bubble inclusion)
● No recalibration required after fluid change
● No installation straight line necessary
● No temperature or pressure compensation necessary
● No periodical recalibration required
The mass flowmeter consists of a sensor and a transmitter. The mass flow meter is equipped with digital signal processor (DSP) -based digital transmission equipment, and integrates digital closed-loop vibration control (DLC) signal processing, sensor calculation and diagnostic functions, and has high measurement accuracy and extensive capabilities. And excellent reliability for you. On-line node configuration, fault diagnosis and data logging can be performed directly through HART or PC via Modbus to communicate with the communicator. The flow meter will not only calculate the process volume flow, cumulative volume and component ratio. TS series flow meters can also provide mass flow, density and temperature online in real time.
Video Display
Product introduction
Coriolis mass flow meters are the most accurate measuring method in the world. The Coriolis measuring principle is used in a wide range of different branches of industry, such as the life sciences, chemicals, petrochemicals, oil and gas, food, and- no less importantly - in custody transfer applications. Coriolis flowmeters can measure virtually all fluids: cleaning agents, solvents, fuels, crude oil, vegetable oils, animal fats, latex, silicon oils, alcohol, fruit solutions, toothpaste, vinegar, ketchup, mayonnaise, gases or liquefied gases.
The Sincerity DMF series U-shape is the standard high performance coriolis mass flowmeters for the process industry. The U shape bent tube meter offers superior performance and high accuracy in virtually any application. From process control in (petro) chemical applications to concentration measurements in the food and beverage industry to custody transfer filling and transport measurements in the oil and gas industry. Its high-end options also make the DMF-1 Series U-shape the optimum device for cryogenic media like Liquefied Natural Gas (LNG) with temperatures down to -200°C / -392°F as well as applications involving high operating temperatures (up to 350°C / 662°F) or pressures (up to 1000 barg / 14504 psig).
Coriolis flow measuring principle
Each Coriolis flowmeter has one or more measuring tubes which an exciter causes to oscillate artificially. As soon as the fluid starts to flow in the measuring tube, additional twisting is imposed on this oscillation due to the fluid’s inertia. Two sensors detect this change of the tube oscillation in time and space as the “phase difference.” This difference is a direct measure of the mass flow.
In addition, the fluid density can also be determined from the oscillation frequency of the measuring tubes. The temperature of the measuring tube is also registered to compensate thermal influences. The process temperature derived from this is available as an additional output signal.
How does a Sincerity Coriolis flow meter measure mass flow and density?
Coriolis mass flow measurement is the MOST ACCURATE FORM for a flow measurement for a wide range of industrial processes. Each Coriolis flowmeter has one or more measuring tubes.
As soon as the fluid starts to flow in the measuring tube, additional twisting is imposed on this oscillation due to the fluid's inertia. Two sensors detect this change of the tube oscillation in time and space as the “phase difference.”
Phase difference= mass flow
Oscillation frequency= density
Product introduction
Flow Range | See charts below |
Connection | ANSI, DIN, JIS, or Sanitary Tri-Clamp flanges, etc. ( Connections can be customized) |
Maximum Pressure | 16 bar (230 psi), [Optional 40 bar (580 psi), up to 1000 bar (14504 psi)] |
Body Material | 304 Stainless Steel |
Measuring Tube Material | 316 L SS, HC Hastelloy, 316L SS + PTFE, HC + PTFE, etc. ( materials can be customized) |
Process Temperature Range | |
Integrate Type | -50 to 15°C (-58 to 302°F) |
Remote Type (-R) | -50 to 35°C (-58 to 662°F) |
Ambient Temperature | -40 to 55°C (-40 to 131°F) |
Working Humidity | (5 to 95%) RH at 25°C (77°F) |
Flow Accuracy | 0.2/ 0.1/ 0.05% (Liquid), 0.5% (gas) |
Density measuring | |
Range | 0.2 to 3.0 g/cm3 |
Error | ± 0.002 g/cm3, ± 0.001 g/cm3 |
Repeatability | 0.001 g/cm3 |
Temperature Accuracy | ±1.0°C |
Protection | IP67 |
Approvals | ATEX, CE, ISO9001, ISO14001, OHSAS18001 |
Communications | RS485 (RTU Modbus), HART (-HART option) |
Pulse Output | 0 to 10 kHz |
Current Output | 4 to 20 mA |
Power Supply | 24VDC, 220VAC (universal power source option) |
Touch screen transmitter: We have our own patented touch screen transmitters with DSP core processor with faster data processing speed.
Light sensing transmitter:Traditional light sensing transmitters. This is the technology for us for the last generation. They have a disadvantage that they will be dis-functional under the strong light in the outdoors.
OEM Nameplate: We support OEM lables. We can customize everything on lables for you, even for the inner software.
Waterproof hole: Waterproof & Explosion- proof threading hole.
With explosion proof rate of ExdibIICT6Gb.
CONNECTIONS:Connections can be specially customized based on your own requirements. GB Flange/ ANSI/ DIN/ JIS Flanges / threaded connections/ Tri-clamp connections, etc.
CONNECTIONS:Connections can be specially customized based on your own requirements. GB Flange/ ANSI/ DIN/ JIS Flanges / threaded connections/ Tri-clamp connections, etc.
CONNECTIONS:Connections can be specially customized based on your own requirements. GB Flange/ ANSI/ DIN/ JIS Flanges / threaded connections/ Tri-clamp connections, etc.
Integrated type/ Separated type: Can be customized as your requirements. For the high temperature measurement with more than 150℃, it is recommended to use the separated type. Standard cable length of 1 meter.
Integrated type/ Separated type: Can be customized as your requirements. For the high temperature measurement with more than 150℃, it is recommended to use the separated type. Standard cable length of 1 meter.
Integrated type/ Separated type: Can be customized as your requirements. For the high temperature measurement with more than 150℃, it is recommended to use the separated type. Standard cable length of 1 meter.
OUTPUT:4-20mA, 0-10KHz, Standard RS 485 communication protocol, HART
OUTPUT:4-20mA, 0-10KHz, Standard RS 485 communication protocol, HART
OUTPUT: 4-20mA, 0-10KHz, Standard RS 485 communication protocol, HART
Material: We can customize the materials for you as your requirements, including SS316L, HC Hastelloy, SS 2205 steel, Titanium, etc.
Shape selection table
Model DMF-1 | Description | ||
1 | Suffix Code | Process Connection Size | Measuring Range (maximum) |
|
S01 | DN1 (1/25”) | 10kg/h |
|
S02 | DN2 (1/8”) | 70kg/h |
|
S03 | DN3 (3/25”) | 150kg/h |
|
S06 | DN6 (1/4”) | 800kg/h |
|
U10 | DN10 (3/8”) | 1500kg/h |
|
U15 | DN15 (1/2”) | 3000kg/h |
|
U20 | DN20 (3/4”) | 7000kg/h |
|
U25 | DN25 (1”) | 13t/h |
|
U40 | DN40 (1.5”) | 22t/h |
|
U50 | DN50 (2”) | 33t/h |
|
U65 | DN65 (2.5”) | 60t/h |
|
U80 | DN80 (3”) | 100t/h |
|
U100 | DN100 (4”) | 160t/h |
|
U125 | DN125 (5”) | 230t/h |
|
U150 | DN150 (6”) | 300t/h |
2 | Code | Accuracy | |
|
A | ±0.5% Mass flow(Gas standard configuration accuracy) | |
N | ±0.2% Mass flow(Liquid standard configuration accuracy) | ||
M | ±0.15% Mass flow | ||
|
H | ±0.1% Mass flow | |
3 | Code | Sensor medium temperature range | |
A | - 50~150℃ | ||
B | -50~ 250℃ | ||
|
C | -50~ 350℃ | |
|
D | -200~ 150℃ | |
4 | Code | Transmitter operating ambient temperature | |
|
E | -20~50℃ | |
|
F | -41~80℃ | |
5 | Code | Pressure | |
|
16 | 1.6MPa(16bar) | |
|
40 | 4MPa (40bar) | |
|
100 | 10MPa (100bar) | |
|
200 | 20MPa (200bar) | |
|
400 | 40MPa (400bar) | |
|
1000 | 100MPa (1000bar) | |
|
XXX | Customized pressure level, maximum upper limit 100MPa | |
6 | Code | Sensor material | |
|
A | Measurement tube material 316L stainless steel, flange material 304 stainless steel (standard material) | |
|
B | Wetted parts material 316L stainless steel, flange material 316L stainless steel | |
|
C | Wetted parts material Hastelloy C-276 | |
|
D | Wetted parts material Alloy20(N08020) | |
|
E | Wetted parts material Ti (ASTM B265) | |
|
F | Wetted parts material Ta (ASTM B708) | |
|
G | Wetted parts material C4 steel (ASTM A600 TI2004) | |
|
H | Wetted parts material HastelloyB3 | |
|
I | Wetted parts material HastelloyC22 | |
|
J | Other possible customized materials need to be communicated and confirmed with technical personnel | |
7 | Code | Sensor housing material | |
|
K | SS304 (Standard material) | |
|
L | SS304L | |
|
M | 316L | |
|
N | Other customized materials and processing methods | |
8 | Code | Process connection | |
|
A | National standard flange HG/20592-2009 (standard configuration) | |
|
B | American standard flange ANSI B16.5 | |
|
C | Ferrule type | |
|
D | Threaded connection | |
|
E | Other customizable special interfaces | |
9 | Code | Transmitter connection mode | |
|
A | Integrative Installation | |
|
B | Seperate Installation | |
10 | Code | Output | |
|
A | RS485 Modbus RTU | |
|
B | RS485 Modbus RTU Hart | |
|
C | FF bus | |
|
D | PD bus | |
11 | Code | Calibration certificate | |
|
E | Factory certificate | |
|
F | Third party certificate | |
12 | Code | Language(can be switched internally) | |
|
A | Chinese | |
|
B | English | |
|
C | Russian | |
|
D | German | |
13 | Code | Electrical interface | |
|
L | M20*1.5 | |
|
K | 1/2"NPT | |
14 | Code | Power supply | |
|
A | 220VAC | |
|
D | 24VDC | |
15 | Code | Explosion prrof | |
|
F | Exd ib II CT6 Gb | |
16 | Code | Protection grade | |
|
A | IP67 |
Choose your own customized coriolis flowmeters
Application |
U-SHAPE |
TRIANGLE TYPE |
MICRO BEND V-HAPE
|
Most common |
CNG/ LNG/ LPG dispensers |
High viscosity and high pressure application |
|
Pipeline size |
DN1-DN150 |
DN10-DN25 |
DN10-DN300 |
Minimum flow rate |
0-0.5kg/h |
0-500kg/h |
0-1000kg/h |
Maximum flow rate |
0-300t/h |
0-13t/h |
0-1500t/h |
Characteristics |
Flow range calibrated can be compressed. The classic typical type with more than 30 years histroy.. |
More popular with pipeline size bigger than dn80, with smaller size and lower pressure drop. Most suitable for high viscosity liquids. |
More popular with cng/lpg/lng dispensers, with even smaller size with most advanced technology. |
Downloads
Typical Applications
General
- Liquids with transient gas entrainment
- Cryogenic or high temperatures (-200…+400°C /-328…+752°F)
- Super critical gases
- Custody transfer (CT)
Chemical and other process industries
- Concentration and density measurement
- Bulk loading
- Batching and blending to reactors
- Hydrocarbon cracking
Oil and gas industry
- Metering skids, bulk loading, pipeline transfer
- "Bypass" density measurement
- Liquefied Natural Gas (LNG)
- Bulk loading
- In-line density measurement
- Multiphase measurement in upstream applications
Food and beverage industry
- Batching, dosing, filling
- Mass flow measurement of ice cream and milk (e.g. at the raw milk reception)
- Measurement of flow, density, specific gravity in brewing processes - Dosing of hop extract
- Measurement of Brix, density and flow in fruit juices
- Dosing of natural oils, grease, vegetables (e.g. spinach) etc.
- CO2 injection in soft drink production
Pharmaceutical industry
- Batching, dosing, filling
- Solvent extraction
Marine industry
- Bunkering and fuel consumption measurement
Pulp and paper industry
- Additives, bleaches and colourants
- Crystallising, solidifying and cryogenic products
Delivery Aftersales service
Accept 2 days fast delivery time.
We provide FULL REFUND if the goods are of bad quality.
2 hours fast reply, 24/7 online.
Multi-national native speaker aftersales team, including English, German, Indian, Chinese, etc.
Aftersales team engineers’ passport ready for 48 countries.
Accept model change even when the goods have already arrived on-site.
ADD:No. 8 building, 3rd. district,I-Town, Gaoli Zhang road,Haidian District, Beijing, China 100095
Mobile:13601110505 010-62469048,62468399,62469399
FAX:010-62469048
Email:vip@bjsincerity.com
PRODUCT
> Coriolis mass flow meter
> Thermal mass flow meter
> Fork Density meter
> Others
> Contact
MESSAGE